덕트 램프 산출방법

 

 

#1. Sheet_산출계산시트

 

 Duct

CFM

 

Temp(°F)               

(V)FPM Lamp size

Lamp Output

(See "Lamp

 output sheet" )

#lamps​ duct sq.ft. kill zone volume  dwell time

intensity required

(Default is 2500µW*sec)  

Lamp intesity@Temp 

 Width

(inches)

Height

(inches)

 Length(ft.)

 
          =÷     =÷ = (×②)/144  =×  =(÷)×60  =2500÷ = (÷45)×⑧

 

 

#2. Sheet_Lamp output sheet"

 

 Lamp model no.

 Lamp Watts

Arc Length 

 UVC Intensity@1M

 UVC Intensity@12"

 400fpm

600fpm 

800fpm 

1000fpm

 GPH345T5L/HO

 28

10

70 

466

419 

373 

326 

 GPH436T5L/HO

 48

14

120

786

707 

629

550 

 GPH770T5L/HO

 75

27

210

1390 

1251

1112 

973 

 GPH843T5L/HO

 87

30

265

1762 

1586 

1410 

1233 

 GPH1554T5L/HO

 145

58

380

2534 

2281 

2027 

1773 

*길이는 인치로 표시됨. 

*램프는 2500㎼*sec 선량을 제공하기 위해 계산된다.

 

1. #1. Sheet의 붉은색 번호에 덕트정보를 입력합니다.

2. 덕트크기에 따라 램프크기를 지정합니다.(#2. Sheet 참조)

3. #1. Sheet ④÷ 계산값이 ⑥의 값이 되며 #2. Sheet의 12"거리에서의 FPM에 따른 값을 산출하여 ⑧에 입력합니다.(200fpm 증가당 출력값은 10%씩 감소함)

4. ⑦에는 #2. Sheet를 참고하여 램프 사이즈(Arc Length)를 입력합니다.

5. ⑩에는 (①*②/144)를 계산값을 입력합니다.(Inches와 ft의 단위환산값 144로 나눠줍니다.)

6. ⑬에는 램프가 한번에 도달할 수 있게 설정한 살균선량값 2500㎼*sec를 ⑫값으로 나눠줍니다.

7. ⑭에는 ⑤값을 기준값 45로 나누고 ⑧을 곱해줍니다. (온도는 화씨로 표기하되 60°C이상 35°C미만값을 입력하지 마세요. 실제 온도가 80°C여도 60°C로 입력합니다.)

8. ⑨에는 권장 램프 갯수가 표시됩니다. 홀수가 되면 다음 숫자까지 반올림합니다.(해당 램프 사이즈로 2등용 또는 4등용 덕트 유닛의 적절한 조합을 선택합니다.)

########